Welding Process
Stick (Constant Current) Welding
Connect welding cables to the "TO WORK and
"ELECTRODE studs. Start the engine. Set the
"Polarity switch to the desired polarity. Set the
RANGEswitch to a setting that is equal to or slightly
greater than the desired welding current. (The
RANGE dial marking indicates the maximum
current
for that range). Fine adjustment of the welding current
is made by adjusting the output CONTROL or
remote control. For best arc stability, use settings
5 through 10.
The Ranger 8 can be used with a broad range of AC
and DC stick electrodes. See Welding Tips 1
included with the Ranger 8 for electrodes within the
rating of this unit and recommended welding currents
of each.
TIG (Constant Current) Welding
The K930-[ ] TIG Module installed on a Ranger 8 pro-
vides high frequency and shielding gas control for AC
and DC GTAW (TIG) welding processes. The TIG
Module allows full range output control. Afterflow time
is adjustable from 0 to 55 seconds.
When using the Ranger 8 for AC TIG welding of
aluminum, the following settings and electrodes are
recommended:
The K930-[ ] TIG Module should be used with the
Ranger 8 on high idle to maintain satisfactory opera-
tion. It can be used in the AUTO position but the
delay going to flow idle after welding is ceased will be
increased if the AFTERFLOW CONTROL is set above
10 seconds.
Wire Feed Welding Processes
(Constant Voltage)
The only Innershield
®
electrode recommended for use
with the Ranger 8 is NR
®
-211-MP. The electrode
sizes and welding ranges that can be used with the
Ranger 8 are shown in the following table:
The Ranger 8 is recommended for limited MIG weld-
ing (GMAW - gas metal arc welding). The recom-
mended electrodes are .030 and .035 L-50 and L-56.
They must be used with a blended shielding gas such
as C25 (75% Argon - 25% CO
2
). The welding ranges
that can be used with the Ranger 8 are shown in the
following table:
RANGER 8
SETTINGS FOR PURE TUNGSTEN
TUNGSTEN RANGE SWITCH APPROXIMATE
DIAMETER (in.) SETTINGS CURRENT RANGE
1/8 70, 90, or 125 80 - 150 Amps
3/32 50, 70, or 90 45 - 130 Amps
1/16 50, or 70 40 - 80 Amps
SETTINGS FOR 1% THORIATED TUNGSTEN
TUNGSTEN RANGE SWITCH APPROXIMATE
DIAMETER (in.) SETTINGS CURRENT RANGE
1/8 70, 90, 125, or 175 80 - 225 Amps
3/32 50, 70, 90, or 125 50 - 180 Amps
1/16 50, 70, or 90 45 - 120 Amps
Diameter Wire Speed Approximate
(in.) Range In./Min. Current Range
.035 80 - 110 75A to 120A
.045 70 - 130 120A to 170A
.068 40 - 90 125A to 210A
Diameter Wire Speed Approximate
(in.) Range In./Min. Current Range
.030 80 - 110 75A to 120A
.035 70 - 130 120A to 170A