Lincoln Electric 8 Welder User Manual


 
F-4
DIAGRAMS
F-4
RANGER 8
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside
the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give the equipment code number..
STARTER
CR1
STARTER
SOLENOID
12 VOLT
IDLER
SOLENOID
213
BATTERY
AC ACB+
SWITCH
REGULATOR
FLYWHEEL ALTERNATOR
B-
HOUR
METER
5E
5D
S4
224B
224
213
"S4" SHOWN
IN "AUTO"
POSITION
ENGINE COMPONENTS
224A
1
2
3
CONNECTOR PIN NUMBERS:
7
6
12
12
34
J1
LEAD COLOR CODE:
B = BLACK
R = RED
W = WHITE
N.A.
B
J5
SOLENOID
FUEL
SHUTOFF
OIL
PRESSURE
TERMINAL BLOCK
(SEE CONN.)
209A
209A
224C
210
B
B
GENERATOR LEAD END
(NOTE CAVITY NUMBERS)
LOCATING TAB
TERMINAL BLOCK
CONNECTION
208
208 (CAVITY #2)
211 (CAVITY #3)
224C (CAVITY #4)
1
3
2
4
211
IGNITION
MODULE
221
B
5H
M18334
215
+
ELECTRICAL SYMBOLS PER E1537
STATOR
REACTOR
S1
WORK
ELECTRODE
CHOKE
D1
S2
D2
ROTOR
C1
CURRENT
SENSOR
PCB1
SLIP RING NEAREST LAMINATION
TURNS
3
W1
W2
C1
S1
E
R1
R2
R4
R5
R6
C1
S2
L1
-
+
+
+
-
R3
STATOR
REACTOR
2
+
10
8
1
7
12
6
6
5
3
9
9
7
200A
200
201A
201
219
200B
3
ENGINE
CROSS
SUPPORT
GROUND SCREW
GND-E
GND-E
GND-G
200B
219
201A
224
215
76
5E
75
77
J1
8
10
5D
7
254A
254
254
254A
B
254A
R1
OUTPUT
CONTROL
75A
76A
77A
1
3
2
4
P5
J5
75A
77A
76A
FIELD
CAPACITOR
AT BLOWER BAFFLE
-
209
+
211
U = BLUE
V = VIOLET
R
R
U
V
W
ENGINE
FOOT
GND-D
GND-C
5F
224A
GND-H
TERMINALS
6
5
5L
115V/230V
5K
GND-D
GND-C
J4
J3
J2
GND-G
5
5L
5K
115V
115V
12
11
11
3E
3E
3C
3A
3A
3B
3B
3D
3D
CB1
35A
35A
CB2
CB3
CB4
15A
15A
15A
15A
CB6
CB5
3
221 (CAVITY #1)
SILVER COLORED
(WHITE WIRES)
K1419-2 Code 10376 & 10538 RANGER 8 KOHLER (CSA) - Wiring Diagram
7-19-96G
CCW
ALL CASE FRONT COMPONENTS SHOWN VIEWED FROM REAR.
N.A. GROUNDING THIS TERMINAL STOPS THE ENGINE.
S3
POSITION
"S3" SHOWN
IN "RUN"
AM1
+
-
208A
S5
START
BUTTON
5H
221
210
208B