TECHNICAL SPECIFICATIONS - POWER WAVE 450
Input Voltages: 230 460
Input Currents
@ 500A/40 VDC 76 38
@ 450A/38 VDC 65 32
Duty Cyc
le Amps Volts at Rated Amperes
230/400/460 - 60% Duty Cycle 450 38 VDC
230/400/460 - 100% Duty Cycle 400 38 VDC
Constant Open Continuous Process
Cir
cuit Voltage Current Range Current Ranges
75 Volts 5-520 Amps GMAW 50-520 Amps
FCAW 40-520 Amps
STICK 30-520 Amps
Pulse Pulse Pulse and Background Pulse
Current Range Voltage Range Time Range Frequency
5-750 Amps 5-55 Volts 100 Microsec - 3.3 Sec 0.15 - 1000 Hz
Type 75°C Type 75°C Type 75°C
Input Duty Input Ampere Copper Wire in Ground Wire in (Super Lag)
Voltage/ Cyc
le Rating on Conduit Conduit or Breaker
Freqency Nameplate AWG[IEC] AWG[IEC] Size (Amps)
Sizes (MM
2
) Sizes (MM
2
)
230/50-60 60% 76 4 (25) 8 (10) 80
460/50-60 60% 38 8 (10) 10 (6) 45
230/50-60 100% 65 4 (25) 8 (10) 80
460/50-60 100% 32 8 (10) 10 (6) 45
Height
Width Depth Weight
905 mm 515 mm 1010 mm 137.9 kg
35.6 in. 20.3 in. 39.8 in. 303.5 lbs.
0° to 40°C -50° to 85°C
INSTALLATION
A-1 A-1
POWER WAVE 450
INPUT - THREE PHASE ONLY
RATED OUTPUT
RATED OUTPUT
RECOMMENDED INPUT WIRE AND FUSE SIZES
PHYSICAL DIMENSIONS
OPERATING TEMPERATURE RANGE STORAGE TEMPERATURE RANGE