Lincoln Electric IM665 Welder User Manual


 
A-1
INSTALLATION
A-1
Weight
Including
Torch Cable
35 lbs.
15.9 kg.
INPUT - SINGLE PHASE / 60 HERTZ ONLY
RATED OUTPUT
OUTPUT
RECOMMEND INPUT WIRE AND FUSE SIZES
REQUIRED GAS FLOW RATE REQUIRED GAS INLET PRESSURE
PHYSICAL DIMENSIONS
TECHNICAL SPECIFICATIONS - PRO-CUT 25 (K1756-1)
Standard
Voltage
Duty Cycle
20% on 115 V
60% on 115 V
100% on 230 V
35% on 115 V
60% on 230 V
Current
Rang
e
12-25 Amps
AC Input
Voltage
at
50/60
Hertz
230V-1Ø
115V-1Ø
115V-1Ø
115V-1Ø
Fuse
(Super Lag)
Circuit Breaker
(Delay Type)
20 AMPS
15 AMPS
20 AMPS
30 AMPS
#14 (2.5 mm
2
)
#12 (4 mm
2
)
#12 (4 mm
2
)
#12 (4 mm
2
)
2 Input Supply Wires
1 Ground Wire
#14 (2.5 mm
2
)
#12 (4 mm
2
)
#12 (4 mm
2
)
#12 (4 mm
2
)
Type 75
o
C
Copper Wire in Conduit
AWG (IEC) Sizes
Depth
16.1 in.
410 mm
Width
6.3 in.
160 mm
Height
10.2 in.
260 mm
Open Cir
cuit
V
oltage
400 VDC
For all plasma cutting applications
Based on U.S. National Electrical Code
Ambient Temperature 30
o
C or Less
Pilot Current
12 Amps
AMPS
15 A
20 A
20 A
25 A
25 A
1Ø Input Current at Rated Output
115/230/1/50/60Hz
115 V : 15 A @ 20%
115 V : 26.7A@ 60%
115 V : 37.7A@ 35%
230 V : 15 A@100%
230 V : 19 A @ 60%
55 PSI @ 240 SCFH
( 3.8 Bar. @ 6800 LHR)
65 to 150 PSI
(4.5 Bar. TO 10.3 Bar.)
25 A
15 A
20 A
25 A
Output
Input Cord
Plug
Size
6-20P or 6-30P or 6-50P
5-15P* or 5-20P* or 5-30P or 5-50P
5-20P* or 5-30P or 5-50P
5-30P or 5-50P
* Included with machine
PRO-CUT 25