Lincoln Electric IM727 Welding System User Manual


 
E-4
TROUBLESHOOTING
E-4
SAE-400 SEVERE DUTY
Observe all Safety Guidelines detailed throughout this manual
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local
Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
CAUTION
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
Welding current too great or too
small compared to indication on the
dial.
Welder has output and no control
No auxiliary power
1. Current Control shaft and han-
dle may have turned slightly in
the insulated bushing of the cur-
rent control brushholder, caused
by turning handle too hard against
one of the stops.
2. Exciter output low causing low
output compared to dial indica-
tion.
3. Current Control set to minimum
and welder output so great that
engine stalls when arc is struck.
1. Local/Remote switch is in wrong
position.
1. GFCI Receptacle may have
tripped. Follow GFCI Receptacle
Testing and Resetting Procedure
in the MAINTENANCE section of
this manual. (GFCI Receptacle is
Optional)
2. Circuit Breakers open.
3. Faulty connections to auxiliary
receptacles.
4. Faulty receptacles.
If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.