INSTALLATION
DEVICENET MODULE
A-4
Configuration Verification
From the file menu select Device Net and then
Configuration. The configuration window will open up
and allow you to verify that the set MAC ID and baud
rate are correct.
If the DeviceNet scanner will not be commanding the
Power Wave then refer under the DeviceNet
Configuration section of the Power Wave Observer
Manual for proper setup. If the DeviceNet scanner
does not support explicit messages, then refer to all of
the following sections in the Power Wave Observer
User Manual: Additional Weld Schedule Variables and
DeviceNet Configuration Section to properly setup the
Power Wave.
From the file menu select Device Net and then
Monitor. The DeviceNet Monitor (shown below) will
display the status of the connection and its data. If
everything is operating correctly, the "Polled IO Cnx
State" will display "Established" and the IO Scans/Sec
will have a non-zero value.