Lincoln Electric V200-T Welder User Manual


 
A-1
INSTALLATION
INVERTEC V200-T
A-1
TECHNICAL SPECIFICATIONS - V200T TIG
For DC TIG Welding at 200A/20% Duty Cycle
Based on the 1996 U.S. National Electrical Code
Code
Number
10463
Volts at Rated Amperes
28
26
25
Type of Output
DC
Input Current at
Rated Output
45/23 A @ 200 A, 33/16 A @ 150 A,
25/13 A @ 120 A
Amps
200
150
120
Maximum Open
Circuit Voltage
80 V
Standard
Voltage
(1)
230/460/1/50/60
Duty Cycle
(2)
20% Duty Cycle
60% Duty Cycle
100% Duty Cycle
Output Current
Range
1 - 200 A
INPUT - SINGLE PHASE ONLY
RATED OUTPUT
OUTPUT
RECOMMENDED INPUT WIRE AND FUSE SIZES
Input
Voltage /
phase/
Frequency
230/1/50/60
460/1/50/60
Input
Ampere
Rating on
Nameplate
45
23
Type 75°C
Copper Ground
Wire in Conduit
AWG (IEC)
Sizes
10 (5.2 mm
2
)
12 (4 mm
2
)
Fuse
(Super Lag)
or Breaker
Size
50
30
Type 75°C
Copper Wire in
Conduit AWG
(IEC) Sizes
10 (5.2 mm
2
)
12 (4 mm
2
)
Height Width Depth Weight
Power 10.04 in. 7.48 in. 17.32 in. Approx. 35 lbs.
Source
255 mm 190 mm 440 mm 16 kgs.
PHYSICAL DIMENSIONS
-20°C to +40°C -25°C to +55°C
OPERATING TEMPERATURE STORAGE TEMPERATURE
(1) Input voltage must be within ±10% of rated value.