Master Appliance GG-100 Glue Gun User Manual


 
Trouble Shooting
Problem
Does not ignite
Excessive Gas
Low Gas Pressure
Low/No adhesive
flow
Probable cause
1. Empty tank
2.
Gas flow either
too high or too low
Gas flow setting is
too high
1. Low fuel
2. Cold fuel
1. No heat
2. Plugged tip
3. Glue gun unit not at
proper operating
temperature
Solution
1. Check window of tank and
refill with butane fuel
2.
Rotate the gas flow adjust-
ment wheel to either increase
or decrease gas flow.
1. Adjust the gas flow
adjustment knob.
2. Re-ignite the gun by
gradually increasing the gas.
1. Refuel with butane gas.
2.
Gently shake to warm fuel up.
1. See information above –
Does not ignite.
2. In the event the applicator tip
is blocking adhesive flow you
may clear the tip with a small
nail or paper clip.
3. Allow unit to heat up for
4 minutes after ignition.
Do not force adhesive.
Size: 8.4” (L) x 2.1” (W) x 8.0” (H)/215mm (L) x 54mm (W) x 205mm (H)
Weight: 14.8 oz. w/o gas
Operating Temp: Approx. 392°F/200°C
Ramp Up Time: 3-4 minutes
Recommended Glue Stick: 1/2” (0.50 inch)
Glue Melt Rate: up to 1.9 lbs. per hour
Ave. Run Time: Approx. 140 minutes (full tank)
Recommended Fuel: Master Ultratane Butane
Fuel Capacity: 20 ml.
Specifications