Middleby Marshall PS360EWB Welding Consumables User Manual


 
Figure 7
Red “LPG.” label placement
(on burner housing)
Figure 8
Conversion information label
THIS APPLIANCE HAS BEEN CONVERTED ON _______________ TO ______________ GAS WITH KIT
NO. ________________ BY _______________ , WHO ACCEPTS THE RESPONSIBILITY FOR
THE CORRECTNESS OF THIS CONVERSION.
MODEL NO. MAIN BURNER ORIFICE SIZE MANIFOLD PRESSURE
INPUT RATING MAXIMUM INLET PRESSURES
Date of conversion
PROPANE
36856
Stated on the
oven’s data plate
175,000 BTU
Signature of technician
performing conversion
.185”/4.70mm
14” W.C./34.9mbar
Measured value
recorded in Step 8.3
Figure 9
Conversion information label placement
Page 4 of 4 P. Jan 98 Rev. B p/n 36857
THIS APPLIANCE HAS BEEN CONVERTED ON _______________ TO ______________ GAS WITH KIT
NO. ________________ BY _______________ , WHO ACCEPTS THE RESPONSIBILITY FOR
THE CORRECTNESS OF THIS CONVERSION.
MODEL NO. MAIN BURNER ORIFICE SIZE MANIFOLD PRESSURE
INPUT RATING MAXIMUM INLET PRESSURES
THIS APPLIANCE HAS BEEN CONVERTED ON _______________ TO ______________ GAS WITH KIT
NO. ________________ BY _______________ , WHO ACCEPTS THE RESPONSIBILITY FOR
THE CORRECTNESS OF THIS CONVERSION.
MODEL NO. MAIN BURNER ORIFICE SIZE MANIFOLD PRESSURE
INPUT RATING MAXIMUM INLET PRESSURES
PS360EWB placement
PS360WB70 placement
Upper oven
label location
Lower oven
label location
9. CONVERSION LABELING
9.1 Remove and discard the round, green “NAT.” label from the
front face of the burner plenum.
9.2 Apply the round, red “LPG.” label (p/n 22500-0065) to the front
face of the burner housing as shown in Figure 7.
9.3 Close the machinery compartment access door.
9.4 Record the information requested on the silver conversion
information label. Figure 8 shows a representation of this label.
9.5 Apply the conversion information label to the front of the
machinery compartment access door, next to the control panel.