Miller Electric 185 DX Welding System User Manual


 
. Complete Parts List available at www.MillerWelds.com
OM-4415 Page 12
SECTION 3 DEFINITIONS
3-1. Symbol Definitions
Engine Choke
Read Operator’s
Manual A
Amperes
V
Volts
Engine Oil Fuel Battery (Engine) Engine
Positive Negative
Alternating Current
(AC)
Output
h
Hours
s
Seconds Time
Protective Earth
(Ground)
Circuit Protector Temperature
SECTION 4 SPECIFICATIONS
4-1. Weld, Power, And Engine Specifications
Welding
Mode
Weld
Output
Range
Rated
Welding Output
Maximum
Open Circuit
Voltage
Generator
Power Rating
Fuel
Capacity
Engine
CC/DC 55 185 A
185 A, 25 V,
20% Duty Cycle
130 A, 25 V,
60% Duty Cycle
100 A, 25 V
100% Duty Cycle
80
Single-Phase,
6 kVA/kW (Peak)
5.5 kVA/kW
(Continuous)
40/23 A,
120/240 V AC,
60 Hz
Standard Model:
1.7 gal (6.9 L)
Tank
DX Model:
5 gal (19 L)
Tank
Standard Model:
Honda GX390
Air-Cooled,
One-Cylinder,
Four-Cycle,
13 HP (390 CC),
Gasoline Engine
(Recoil-Start)
DX Model:
Kohler CS12.75
Air-Cooled,
One-Cylinder,
Four-Cycle,
12.75 HP (360 CC),
Gasoline Engine
(Electric-Start)