Miller Electric Big 40 C Welding System User Manual


 
OM-4427 Page 25
5-11. Connecting To Remote 14 Receptacle RC14 On CC/CV Models
Socket* Socket Information
24 VOLTS AC
A 24 volts ac. Protected by circuit
breaker CB5.
24 VOLTS AC
B Contact closure to A completes
24 volt ac contactor control
circuit.
C Output to remote control:+10
volts dc in MIG or Stick mode;
0 to +10 volts dc in TIG mode.
REMOTE
OU
TP
U
T
D Remote control circuit common.
OUTPUT
CONTROL
E DC input command signal: 0 to
+10 volts from min. to max. of
remote control with Voltage/
Amperage Adjust control at
max.
OR
115 VOLTS AC
I
115 volts, 10 amperes, 60 Hz
ac. Protected by circuit breaker
CB6.
J
Contact closure to I completes
115 volt ac contactor control
circuit.
Ref. 803 602
GND
K Chassis common.
NEUTRAL G Circuit common for 24 and 115
volt ac circuit.
*The remaining sockets are not used.