0 100 200 300 400 500 600 700
4-3. Volt-Ampere Curves For CC Models
202 666-A
The volt-ampere curve shows the
minimum and maximum voltage
and amperage output capabilities of
the welding generator. Curves of all
other settings fall between the
curves shown.
DC AMPERES
DC VOLTS
Ranges
165 350
210 Max
100 250
45 85
65 120
Notes