Miller Electric D-75D Welder User Manual


 
OM-228 322 Page 16
5-9. Installing Non-PD (Old Style) Wire Guides
Ref. 804 192-C
Installing wire guides with non-
PD (old-style) drive rolls
. Non-PD (old-style) wire guides
and drive rolls should be used
with 5/64 in (2.0 mm) and larger
diameter wire.
1 Pressure Door Assembly
2 PD Inlet Guide
3 Intermediate Guide
4 Set Screw
5 Guide Holder
6 Exit Guide
Open pressure door assembly.
Lift up drive roll swing arms.
Install PD inlet guide.
. Do not tighten set screw to se-
cure inlet guide.
. Set screw may be used to se-
cure PD inlet guide replace-
ments such as wire straighten-
ers or conduit adapters.
Remove screw securing intermedi-
ate guide holder. (Guide holder is
located between the lower front
and rear drive roll carriers.)
Rotate guide holder 180 degrees
and reinstall.
Install intermediate guide into guide
holder and tighten set screw.
Loosen set screw, insert exit guide
into block near brass power pin gun
connection and secure with set
screw.
. When using smaller diameter
inlet guide (219108) with non-
PD (old style) drive rolls, a 1/4
in (6 mm) gap will be present
between the guide and drive
roll.
1
Tools Needed:
1/16, 1/8, 5/32 in
6
5
3
2
4