Miller Electric Digi-Meter RMS (AC-DC) Welding System User Manual


 
OM-867 Page 5
SECTION 5 MAINTENANCE & TROUBLESHOOTING
WARNING
ELECTRIC SHOCK can kill.
Do not touch live electrical parts.
Turn Off welding power source, and disconnect
input power before inspecting, maintaining, or
servicing. Stop engine on welding generator.
HOT PARTS can cause severe burns.
Allow cooling period before maintaining or servicing.
Maintenance and troubleshooting to be performed only
by qualified persons.
swarn8.1* 10/91
5-1. Routine Maintenance
See
Section
7
Replace
Unreadable
Labels
Turn Off all power before maintaining.
ST-084 121-A
3 Months
OR
Blow Out
Or
Vacuum
Inside
6 Months
Tape Or
Replace
Cracked
Weld
Cable
Clean
And
Tighten
Weld
Terminals
3-2
Figure 5-1. Maintenance Schedule
5-2. Troubleshooting
READ SAFETY BLOCKS at start of
Section 5 before proceeding.
WARNING
Table 5-1. Welding Trouble
Trouble Remedy Section
Unit completely inoperative; no meter
display.
Be sure input power cord is plugged in and that receptacle is receiv-
ing input power.
3-2
Incorrect meter display. Check weld cable, input power, and voltage sensing connections. 3-2
Turn off high frequency, if applicable. 3-2
No display on one meter only; other me-
ter works.
Check connections to meter module; tighten or clean if necessary.
Check and replace meter module if necessary.
Have Factory Authorized Service Station/Service Distributor check
digital meter board PC1.
Erratic meter display. Check connections to meter shunt; tighten or clean if necessary.
Meters do not hold display with Std./Hold
switch in Hold position.
Place switch in Std. position when welding amperage is below re-
quired minimum.
Figure 4-2
Have Factory Authorized Service Station/Service Distributor check
digital meter board PC1.