Miller Electric Engine-Driven Welder/AC Generator Welding System User Manual


 
Patented self-cooling stator barrel design
directs airflow for maximum cooling and
allows the Bobcat to perform at 100%
duty cycle even in 104˚ F (40˚ C) heat!
Bulletproof technology eliminates use of complicated circuit boards.
Engine Specifications (Subject to change without notice.)
Welding
Mode
CV/DC
CC/DC
CC/AC
Process
MIG/FCAW
Stick/TIG
Stick/TIG
Weld Output Rated
at 100% Duty Cycle
(at 104˚ F/40˚ C)
200 A at 20 V
210 A at 25 V
225 A at 25 V
Amp/Volt
Ranges
19–28 V
50–210 A
50–225 A
Generator Power
Single-Phase
Peak: 10,500 watts
Continuous: 9500 watts 120/240 VAC, 84/42 A
Three-Phase
Peak: 11,000 watts
Continuous: 10,000 watts 480 V, 13 A
Sound Levels
at Rated Output,
7 m (23 ft)
75.5 dB
(100.5 Lwa)
Net
Weight
540 lb
(245 kg)
Dimensions
H: 33 in
(838 mm)
W:20 in
(508 mm)
D: 45-1/2 in
(1156 mm)
Specifications (Subject to change without notice.)
Engine Brand
Kohler:
3 year mfg.
warranty
Horsepower (HP)
23 HP (gas),
25 HP (LP) at 3600 RPM
Weld Speed
3600 RPM
Idle Speed
2300 RPM
Type
V-Twin cylinder,
4-cycle, OHV, industrial,
air-cooled, gasoline
Fuel Capacity
12 gal (45 L)
Oil Capacity
1.75 qt (1.7 L), 2 qt (1.9 L) with filter
1
5
3
2
4
6
7
8
Function Guide
1. Engine Hour Meter is convenient for monitoring maintenance intervals.
2. Weld Process Selector Switch makes choosing between Stick, Wire
and TIG processes easy. Switch also auto matically changes polarity
with process selection to make sure the machine is set up properly to
weld with little effort or knowledge.
3. Coarse Range Control. Three Stick/TIG and one Wire range are
available for output control. Stick/TIG ranges are designed to electrode
diameters (3/32", 1/8", 5/32") making these models very easy to set.
4. Fine Adjust Control makes it easy to fine tune amperage within a
coarse range. Set control above 7 for best power while welding and to
10 for generator-only use.
5. Engine Control Switch is used to start the engine and then select
between Auto Idle and High Speed Lock.
6. Engine Choke Control is used for easy engine starting.
7. 120 VAC and 240 VAC* Covered Receptacles with Circuit Breakers
meet/exceed OSHA/CSA requirements for job site safety (optional
120 VAC GFCI receptacles available).
*For matching plug, order #119 172.
8. 480 VAC* Covered Receptacle with Circuit Breaker meet/exceed
OSHA/CSA requirements for job site safety.
*For matching plug, order #165 963.
Make deadlines, not excuses.
•68% of service technicians, managers
and owners, recommend the Bobcat
over the competition.
•98% of current owners are “satisfied
to very satisfied” with the Bobcat*.
*Based on an independent survey of
thousands of Bobcat owners.
Bobcat 68%
Others
Technician Recommendations
The Bobcat
Competitive
Advantage
Rated #1 in Reliability
Large 3–4 gauge leads are lugged to
heavy-duty range switches for field-
proven durability. Dust cover protects
switches from dirt and grit. Compare to
light-duty switches with smaller 6–10
gauge leads on competitive machines.
2