Miller Electric M-10 Gun Welder User Manual


 
OM-1330 Page 18
4-14. Selecting A Location And Connecting Input Power
Y Special installation may be required
where gasoline or volatile liquids
are present see NEC Article 511 or
CEC Section 20.
For 115 volts ac input power, a 15 or 20
ampere individual branch circuit protected
by time-delay fuses or circuit breaker is
required. For 230 volts ac input power, see
Section 4-11.
1 Rating Label
Supply correct input power.
2 Power Cord Connector
3 Plug NEMA Type 5-15P
4 Receptacle NEMA Type 5-15R
(Customer Supplied)
5 Plug NEMA Type 5-20P (Optional)
6 Receptacle NEMA Type 5-20R
(Customer Supplied)
7 Plug NEMA Type 6-50P
8 Receptacle NEMA Type 6-50R
(Customer Supplied)
Select plug for power supply receptacle
available at site. Install plug onto power
cord adapter. As threaded collar is
tightened, push plug onto adapter until
collar is completely tight.
Connect plug to receptacle.
9 Cylinder Support Bracket
Holes in the bracket provide a location to
store the unused power cord plugs.
18 in (457 mm) of
space for airflow
Y Do not move or operate unit
where it could tip.
Ref. 803 862-C
3
1
2
4
56
78
9
Y Do Not cut off power cord connector and rewire. The power cord
connector and plugs will work with standard NEMA receptacles.
Modifying power cord, connector, and plugs will void product
warranty.