Miller Electric OM-2241 Welder User Manual


 
OM-2241 Page 14
3-9. Remote 14 Receptacle RC8
Ref. 800 166-D
Y Turn off power before con-
necting to receptacle.
1 Remote 14 Receptacle RC8
Connect feeder to RC8.
AJ
B
K
I
C
L
NH
D
M
G
E
F
1
3-10. Remote 14 Receptacle RC8 Information
Socket Information
24 VOLTS AC
A 24 volts ac. Protected by circuit breaker CB2.
24 VOLTS AC
B Contact closure to A completes 24 volts ac contactor control circuit.
C Command reference; 0 to +10 volts dc.
REMOTE OUTPUT CONTROL
D Remote control circuit common.
E 0 to +10 volts dc input command signal from remote control.
F Current feedback; 1 volt per 100 amperes.
H Voltage feedback; 1 volt per 10 arc volts.
115 VOLTS AC
I 115 volts, 15 amperes, 60 Hz ac. Protected by circuit breaker CB1.
115 VOLTS AC
J Contact closure to I completes 115 volts ac contactor control circuit.
GND
K
G
Chassis common.
Circuit common for 24 and 115 volts ac circuits.
REMOTE POWER ON/OFF
To remote On/Off switch.
REMOTE POWER ON/OFF
*
To remote On/Off switch.
REMOTE VOLTAGE SENSING
* Voltage sensing signal from Negative (−) weld output terminal.
REMOTE VOLTAGE SENSING
* Voltage sensing signal from Positive (+) weld output terminal.
* Not Used