Miller Electric OM-234 016D Welder User Manual


 
OM-234 016 Page 15
3-5. Connecting Spool Gun To Renegade 180
804 755-B
1 Drive Assembly
2 Spool Gun
3 Gun Securing Knob
4 Gun End
Loosen gun securing knob. Insert
end through opening until it bottoms
against drive assembly. Tighten
gun securing knob.
. Be sure that gun end is tight
against drive assembly. Ex-
posed O−rings will cause
shielding gas leakage.
Spool gun must be inserted
completely to prevent leakage of
shielding gas.
5 Gun Trigger Plug
Insert plug into receptacle, and
tighten threaded collar.
6 Spool Gun/MIG Gun Switch
Place switch in Spool Gun position.
7 Polarity Changeover Terminal
Block
To make proper polarity connection,
see welding power source Owner’s
Manual. Typically, DCEP is used for
solid and aluminum wire.
Close door.
6
5
7
1
3
2
4