Miller Electric S-22P12 Welder User Manual


 
OM-1569 Page 13
3-5. 14-Pin Plug Information
Pin* Pin Information
A 24 volts ac with respect to socket G.
AJ
B Contact closure to A completes 24 volts ac contactor control circuit.
AJ
B
K
I
G Circuit common for 24 volts AC circuit.
C
L
NH
C +10 volts dc output to remote control with respect to socket D.
D
M
G
E
F
D Remote control circuit common.
E 0 to +10 volts dc input command signal from remote control with respect to socket D.
*The remaining pins are not used.
3-6. Setting Optional Wire Speed Meter Range Switch
Ref. ST-130 076
12
12
0-400 ipm
(0-10.2 mpm)
0-800 ipm
(0-20.2 mpm)