OM-2248 Page 12
4-6. Connecting Work Clamp
802 463-A
1 Work Clamp
2 Workpiece
Connect work clamp to a clean,
paint-free location on workpiece, as
close to cutting area as possible.
1
2
4-7. Connecting Input Power
802 460-B
Check input voltage available at
site.
1 Grounded 120 VAC
Receptacle (Non-CE Models)
A 120 volt, 20 ampere individual
branch circuit protected by
time-delay fuses or circuit breaker
is required (see Section 4-1).
2 Plug From Unit
Select extension cord of 12 AWG
for up to 53 ft (16 m).
3 Grounded 230 VAC
Receptacle (CE Models)
A 230 volt, 10 ampere individual
branch circuit protected by
time-delay fuses or circuit breaker
is required (see Section 4-1).
4 Plug From Unit (Customer
Supplied)
Select extension cord of 14 AWG
for up to 133 ft (41 m).
Y Special installation may be
required where gasoline or
volatile liquids are present −
see NEC Article 511 or CEC
Section 20.
2
1
2
3
4