OM-233 045 Page 23
5-2. Meter Functions
. The meters display the actual weld output values for approximately three seconds after the arc is broken.
Mode Meter Reading At Idle
Scratch Start TIG (GTAW)
Actual Volts (OCV) Preset Amps
VA
80.0 85
Lift-Arc Trigger
Hold TIG (GTAW)
VA
Blank Preset Amps
85
TIG (GTAW)
Blank Preset Amps
VA
85
MIG (GMAW)
Preset Volts Blank
VA
24.5
Pulsed MIG
(GMAW-P)
Pulse Display Pulse Display
VA
PPP PPP
Remote
Control SMAW
Blank Preset Amps
VA
85
Panel Control
SMAW
Actual Volts (OCV) Preset Amps
VA
80.0 85
Voltage-Sensing
Wirefeeder
Flashes (OCV) And Preset Blank
VA
80.0