Milwaukee 48-59-0255 Battery Charger User Manual


 
4 5
When to charge the battery pack
Charge your battery pack before you use
your tool for the first time and when your
tool no longer performs with the power
and torque needed for the job. Never com-
pletely discharge the battery pack.
New battery packs reach full loading ca-
pacity after 4-5 chargings and
dischargings. Battery packs which have
not been used for some time should be
recharged before use.
Standard charging times
Standard charging time is approximately
one hour. Charging time varies depending
on the battery temperature, charge needed
and the type of battery pack being
charged. For example, if the battery pack
does not require a full charge, the charg-
ing time will be less than one hour.
Effects of temperature on charging
Battery packs are affected by temperature.
The charger will sense battery temperature
and will charge the battery at the most rapid
rate when its temperature ideal (between
41°F (5°C) and 113°F (45°C). When the
battery temperature is outside of this range,
the charger will supply enough current to
keep the battery pack in its current state to
prevent damage to battery.
OPERATION
Charge only MILWAUKEE 12, 14.4 and 18 Volt battery packs in
this charger. Other types of batteries may explode causing
personal injury and damage.
WARNING!
Connect Charger to AC
Power Source
Light Off
Insert Battery
Flashing Light
Charge pending until
battery temperature is
below 113°F (45°C).
Battery temperature
41°F - 113°F (5°C - 45°C)
Charging
Continuous Light
Battery too cold
less than 41°F (5°C)
Flashing Light
Battery too hot
over 113°F (45°C)
Charge pending until
battery temperature is
above 41°F (5°C).
Charger Ready
Light Off
Battery is charged/
Maintenance charging
Automatic start
When a hot or cold battery pack is inserted
into the charger, charging will begin auto-
matically if the battery reaches the correct
charging temperature.
Maintenance charge
Batteries discharge at a rate of about 1%
per day. The Maintenance Charge feature
keeps the battery pack fully charged when
the battery pack is stored in a charger that
is plugged in. The Maintenance Charge
automatically begins after the battery pack
is fully charged. During Maintenance
Charge,the control light will be off.
Charging the Battery Pack