4
DC voltage normal
DC voltage higher than 15.4 volts
DC voltage lower than 10.5 volts
1
3
4
5 6
AC power to AC heater
DC power to divider heater
DC power to gas valve
DC power to ignition circuit
DC power to
light switch
1
2
3
Sensing burner flame
Food compartment light
is off and door is closed
Thermistor sensing
fin temperature
Screen Erase Fault History Data
Screen 6 provides a way to erase stored fault history
from memory. To erase stored fault history:
1. Press and hold the
TEMP
SET
button when and
display.
2. Release the
TEMP
SET
button when and
display.
3. Wait five seconds.
4. Press and hold the
TEMP
SET
button until and
display again.
Press the
MODE
button to bring up screen 7.
Screen Power Board DC Voltage Status
Screen 9 display power board DC voltage status using
lighted LED segments. The illustration below provides
DC voltage status and assigned LED segments. If DC
voltage at the power board within normal range (10.5
to 15.4 Vdc), LED segment 4 will be on.
Screen Power Board Inputs
Screen 7 displays "live" power board inputs using
lighted LED segments. The illustration below provides
"live" inputs information and assigned LED segments. If a
power board input is active or "live", its assigned
LED will light.
Screen Power Board Outputs
Screen 8 display "live" power board outputs using
lighted LED segments. The illustration below provides
"live" outputs information and assigned LED segments.
If the power board output is active or "live," the
assigned LED will light.
Press the
MODE
button to bring up screen 8.
Press the
MODE
button to bring up screen 9.
Press the
MODE
button to return to screen 1.