Norcold N84X Work Light User Manual


 
www.norcold.com/cda
12
Refrigerator Service ManualN6XX/N8XX Models
F/no FL Fault Code – Burner failed to ignite or reignite
Air gap
1/8 to 3/16
inch?
Burner
clean?
Before beginning this procedure make sure:
RV LP gas tank valve is open.
Refrigerator solenoid gas valve manual shutoff is open.
LP gas pressure at the solenoid gas valve pressure tap is 10.5.
Models and fault indicator displayed.
ON
GAS
N62X/N82X
LP GASAC
AUTO
Clean and service burner.
See page 30.
NO
YES
Check that electrode tip-to-
burner air gap is correct.
NO
Set electrode-to-burner air gap
1/8 to 3/16 inch.
YES
Continuity?
Check spark/sense electrode
assembly for continuity.
NO
Replace spark/sense electrode
assembly.
Voltage?
YES
Check voltage across power
board terminals GV and
GV GND.
NO
Replace power board.
Continuity?
YES
Check gas valve solenoid
wires for continuity.
NO
Replace gas valve wires.
YES
Check gas valve solenoid
resistance.
.
NO
Replace gas valve.
79 to 85 ?
Check burner.
YES
Faulty or obstructed gas valve.
Replace gas valve.
N61X/N81X
N64X/N84X
D
i
s
p
l
a
y
A
l
t
e
r
n
a
t
i
n
g
Audible
Alarm
GAS LED
flashing
constantly