INSTALLATION
OPTION #2 - IN WALLS ALONG BASE BOARDS
Refer to Figure 3 (ACCESS TO PIPING FROM BELOW)
1. Locate studs (1) in the wall at the location VacPan™ will be installed.
2. VacPan™ should be located tight to one side in stud space.
3. Drill a small reference hole (2) through the floor under area of VacPan™. This will establish location from basement.
4. From below, use hole saw to remove wood floor and wood plate at location of VacPan™ between studs in wall cavity to
provide access hole (3) from below.
5. Using a 1
1
/2" hole saw, remove a 6
3
/4" long slot (4) in baseboard tight to one stud.
Refer to Figure 4
6. Make wire connections to brass terminal and sprig terminal screws (5).
7. Secure VacPan™ (6) to baseboard using #6 screws provided.
8. From below, reach through hole (3) in stud space and push elbow (7) onto VacPan™ (6).
9. Make piping connections (8) as required to tie into existing central vac piping.
FIGURE 3
FIGURE 4
1
1
2
4
3
3
6
7
8
5