OMEGA FP-5060 Series Micro Flow Sensor
4. Fitting Installation
CAUTION:
• Maximum pipe fi tting torque: 10 ft - lbs (13 N m).
• DO NOT overtighten. Failure to observe torque specifi cation may permanently damage sensor ports.
5. Calibration
The K-Factors listed below represent the number of pulses the sensor will generate for each engineering unit of fl uid which passes.
They are listed in U.S. gallons, liters and mL by sensor model:
Technical Notes:
Compatible fi ttings (customer supplied): Female union (shown), reducer, or hose barb type.
Always apply thread sealant to sensor port threads to prevent leakage.
Sealant
FP-5060
Pipe fitting Pipe
Pipe fittingPipe
3. Surface Mount Instructions
1
Mounting surface
2
Remove sensor then use correct
screws for panel material.
Mounting surface (top),
68 mm (2.68 in.) bolt circle
120°
#6 or M3 metric
screws recommended
Mounting surface (side)
Sensor
Model
PULSES PER
U.S. GAL
PULSES PER
LITER
PULSES PER
mL
FP-5061 9950 2629 2.629
FP-5062 9950 2629 2.629
FP-5063 3160 834.9 0.835
FP-5064 3160 834.9 0.835