Omega Engineering JD 4045 Air Compressor User Manual


 
10
P/N: 307271
1.4 SERVICING
1. Before servicing compressor, relieve receiver pressure and allow to cool.
2. Be sure all access panels are opened and/or removed.
3. Wipe up all spills resulting from servicing.
4. Disconnect the grounded (negative) battery connection before making repairs or cleaning inside
the enclosure.
5. Do not use flammable solvents for cleaning the compressor.
6. Radiator coolant is under pressure. Do not remove radiator cap quickly, it may cause spray of
scalding coolant and severe burns to operator.
7. Make repairs only in clean, dry and well-lighted and well-ventilated areas.
8. Keep all parts of the body and any hand held tools or other metal objects away from exposed live
parts of the electrical system.
9. Replace damaged fuel tanks or lines immediately. DO NOT WELD on or near fuel tanks or lines.
10. Make sure all personnel are out of the compressor before closing and/or replacing panels.
1.5 LIFTING
1. If the compressor is provided with a lifting bail, then lift by the bail. If no bail is provided, then lift
by sling.
2. When lifting by helicopter, use a sling. Do not lift by unit lifting bail.
3. Inspect the entire lifting, rigging and supporting structure to ensure it is in good condition and has
a rated capacity of at least the gross weight of the compressor plus 50%.