Oneida Air Systems 2005c3HP Dust Collector User Manual


 
O.A.S. 2005
c
3HP High Vacuum Owners Manual
I. System Start-Up Information
1. Read the installation and maintenance instructions as well as the recommended
safety practices in this manual.
2. Install Ductwork completely:
A.) Seal ductwork with silicone sealant or duct tape.
B.) Have Dust Bin in place and sealed.
3. Have licensed electrician wire Fan / Blower according to wire diagram in this
owners manual.
4. Have licensed electrician check current draw on motor with all gates open. Current
draw should not exceed maximum motor amperage. (OAS is not responsible for
destroyed motors.)
Caution
The Dust Collector & Fan/Blower is heavy. Handling and
installation should always be performed by experienced and
trained personnel who have experience with rotary equipment.
In addition to the following instructional manual, care should
be taken to ensure compliance with specific safety
requirements mandated by federal, state and local codes.
Warning
Do not operate Fan / Blower without connecting ductwork.
Never operate Fan/Blower without belt and shaft guard in
place. Keep clear of exhaust. Keep hands and objects clear
of inlet and outlet.
Warning
Check amperage draw during operation with all blast gates
open. Make certain amperage is not outside operating limit
indicated on motor plate! If amperage is too high - shut down
immediately! (See Troubleshooting section.)
2