Oneida Air Systems 2005c3HP Dust Collector User Manual


 
O.A.S. 2005
c
3HP High Vacuum Owners Manual
Cyclone
Barrel
Cyclone
Cone
2.
3.
2. Clamp the fan housing and cyclone barrel to
the cyclone cone with the clamp ring. Note: the
fan / blower and the cyclone barrel are very
heavy. The system will be top heavy. One method
is to lay the stand down, then bolt the cyclone
with the fan / blower to the stand. The iron ring
will slide into stand.
3. Tip the fan housing and cone upright. The
system is very top heavy.
4. Bolt the elbow-cartridge housing to the fan
housing outlet (rectangular). Clamp the cartridge
to the flat plate. Clamp the dust bins to the
bottom of the cartridge filters.
Continued on next page.
7
Pleated
Cartridge
Filters
(Do not remove
fabric straps
from cartridge.)
Removable
Dust
Container
5hp Integral
Fan Blower
Angle Iron
Stand
Outlet
Inlet
Elbow
Square-to-Round
Cone
Cyclone
Clamp
Ring
VI. Assembly Instructions
Cyclone
Barrel
Air Inlet
Fan / Blower
1.
1. Orient the blower housing to match the stand
configuration and the desired angle for the cyclone inlet.
Bolt the fan / blower to the cyclone barrel using the
hardware taped on the motor.
Bolts are already welded on Fan/Blower unit. Put strip
of the neoprene gasket around the cyclone barrel behind
the bolt holes. Then put bolts through holes in barrel.
Put flat washer on bolt. then lock washer, then hex nut.
Cyclone Inlet and Fan / Blower are independent.
Filters can be to the right or left of the unit.
Air
Outlet
Neoprene
Gasket
Material
16 ea. 3/8 Flat Washers, Lock Washers and Hex Nuts
Fan / Blower is shipped strapped to Cyclone Barrel. It is
NOT attached to the unit. You must bolt them together.
Follow the instructions below.
One bolt hole
on each side.
Do NOT use
hook on motor
to lift unit.