Pelco C1498M-B Welder User Manual


 
Pelco Manual C1498M-B (7/99) 9
225 ON OFF OFF OFF OFF ON ON ON
226 OFF ON OFF OFF OFF ON ON ON
227 ON ON OFF OFF OFF ON ON ON
228 OFF OFF ON OFF OFF ON ON ON
229 ON OFF ON OFF OFF ON ON ON
230 OFF ON ON OFF OFF ON ON ON
231 ON ON ON OFF OFF ON ON ON
232 OFF OFF OFF ON OFF ON ON ON
233 ON OFF OFF ON OFF ON ON ON
234 OFF ON OFF ON OFF ON ON ON
235 ON ON OFF ON OFF ON ON ON
236 OFF OFF ON ON OFF ON ON ON
237 ON OFF ON ON OFF ON ON ON
238 OFF ON ON ON OFF ON ON ON
239 ON ON ON ON OFF ON ON ON
240 OFF OFF OFF OFF ON ON ON ON
241 ON OFF OFF OFF ON ON ON ON
242 OFF ON OFF OFF ON ON ON ON
243 ON ON OFF OFF ON ON ON ON
244 OFF OFF ON OFF ON ON ON ON
245 ON OFF ON OFF ON ON ON ON
246 OFF ON ON OFF ON ON ON ON
247 ON ON ON OFF ON ON ON ON
248 OFF OFF OFF ON ON ON ON ON
249 ON OFF OFF ON ON ON ON ON
250 OFF ON OFF ON ON ON ON ON
251 ON ON OFF ON ON ON ON ON
252 OFF OFF ON ON ON ON ON ON
253 ON OFF ON ON ON ON ON ON
254 OFF ON ON ON ON ON ON ON
Receiver Address Switch Setting
SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8
Table C. Switch Settings for SW2 – D-Type Control (Continued)
NOTE:
For Coaxitron
®
controls, SW2 is not used; set all switches OFF.
For P-type control systems, refer to Table B.
OPERATION
The red LED in the back box interconnect door lights when power is turned on, and the fan
exhausts heat from inside the back box when the dome drive is installed. If you have an
outdoor pendant model with a heater, heater elements in the back box turn on at 70°F
(21°C) and off at 85°F (29°C). The heater element in the lower dome turns on at 40°F (4°C)
and off at 60°F (16°C). The interconnect door fan and heater fans in the outdoor back box
operate continuously.
POWER-UP DISPLAY
When the dome is powered up or reset, the monitor displays the selected protocol, revision
number, and other information, which remains until the dome moves. The information
displayed depends on the selected protocol and the choice made on the menu for
selectable power-up mode. As a default, the dome goes to a random position.
The control system protocol (C, D, or P) appears. C is for Pelco’s Coaxitron
®
control
system. D-type control is RS-422 compatible with Pelco’s CM6700, MPT9500, and CM8500
controllers or with American Dynamics control systems using the AD2083 Translator. P-type
control is RS-422 compatible with Pelco’s CM6700 and CM9750/CM9760 control systems.
For D and P protocols, the device address, baud rate, parity (N), number of data bits (8), and
number of stop bits (1) appears. For D protocol, “32 presets” appears if the 32-preset mode is
selected (SW1-7 ON). “CM9500 mode” appears if CM9500 mode is selected (SW1-8 ON).
NOTE:
The dome will stop
operating if voltage at the
dome drops below 18 VAC.
It will turn back on and go
through its start-up routine
when the voltage exceeds
18 VAC.