Pentair XLS600 Air Compressor User Manual


 
The heat pump in equipped with
a internal "Automatic Bypass"
valve. A variable rate spring
valve is used to regulate the wa-
ter flow through the heat ex-
changer. Steady flow will be de-
livered over a wide range of flow
rates. This automatic valve can
handle a maximum flow rate of
90 gallons per minute.
The automatic valve will com-
pensate for flow loss due to nor-
mal filter debris accumulation or
changes if flow due to valving
and other conditions.
See chlorinator
placement guidelines.
PLUMBING CONNECTIONS
Filtered Water “IN” on the LEFT front.
Heated Water "OUT" on the RIGHT front.
The plumbing inlets are "slip" p.v.c. pipe that will accept
a 2 inch p.v.c. glue fitting. The pipe is left plain so you
can adapt to your needs. Use p.v.c. cleaner to prime the
fitting and pipe. Use a quality medium body p.v.c. glue.
FOR PUMPS UP TO 2 H.P. OR 90 G.P.M. MAX.
SEE PAGE 19 FOR LARGER WATER PUMPS.
Automatic Bypass Valve
Variable Rate Self Adjusting
up to 90 G.P.M.
PLUMBING & WATER FLOW
INTERNAL AUTOMATIC BYPASS
See mandatory chlorinator placement
and install of the loop & check valve.
Water
Pump
Filter
Chlorinator or
Chemical Feeder
Heater
Chlorinator Loop & 2 lb. Chem.
Resistant Check Valve
WATER IN
WATER
OUT
1. PUMP
2. FILTER
3. HEATER
4. LOOP & CHECK
5. CHLORINATOR
6. RETURN TO POOL
Warning
No Chemicals In
Skimmer !!
IN
OUT
Special
Compression Fitting
Sacrificial Chemical Protec-
tion Piping
Marine Grade
Cupronickel
Heat Exchanger
Encased in
Closed Cell Foam
Free Flow
Flexible
Water Inlets
WARNING