8
Never point tool at yourself or others.
Always connect tool to air supply before loading fasteners (Fig. 18).
Do not load fasteners with trigger or safety depressed.
Only use approved Porter-Cable fasteners.
Operator and others in work area MUST wear safety glasses with side
shields. Always wear ANSI Z87.1 approved safety glasses, and ANSI
S3.19 approved hearing protection when preparing or operating the
tool.
Never use a tool that is leaking air, has missing or damaged parts, or
requires repair.
2. Pull follower (A) Fig. 19, all the way to the rear, until it latches.
3. Insert a strip of approved fasteners, see Fig. 20. Orient fasteners with
points down. Slide fasteners forward to the front of the magazine. The
magazine will hold two full strips of fasteners.
4. Depress follower release lever (A) Fig. 21, allowing the follower to slide
forward against the fasteners.
5. Adjust directional exhaust deflector
(A) Fig. 22, so that the exhaust air
blast will be directed away from the
operator. The exhaust deflector
provides seven detented positions for
directing the exhaust blast away from
the operator. Grasp the deflector and
rotate it to the desired position for the
current application.
Fig. 18
Fig. 19
Fig. 21
A
Fig. 22
Fig. 20
A
A