Porter-Cable N039112 Air Compressor User Manual


 
12 - ENG
2. Turn regulator knob clockwise to increase pressure and stop when desired
pressure is reached.



The compressor is ready for use.
MAINTENANCE
CUSTOMER RESPONSIBILITIES

each use
Daily

each
use
See tank
warning
label
Check Safety Valve
X
Drain Tank
X
Remove tank from service
X(1)
1- For more information,
call our Customer Care Center at 1-(888)-848-5175
       


        

NOTE: See Operation section for the location of controls.
TO CHECK SAFETY VALVE


       
equipment: ANSI Z87.1 eye protection (CAN/CSA Z94.3) with side shields.
Before starting compressor, pull the ring on the safety valve to make sure that the
safety valve operates freely. If the valve is stuck or does not operate smoothly, it
must be replaced with the same type of valve.
TO DRAIN TANK
Air tanks contain high pressure air.
ANSI Z87.1
eye protection (CAN/CSA Z94.3) when draining as debris can be kicked up

Use ear protection [ANSI S12.6 (S3.19) hear-
ing protection]
NOTE: All compressed air systems generate condensate that accumulates in
any drain point (e.g., tanks, filter, aftercoolers, dryers). This condensate contains
lubricating oil and/or substances which may be regulated and must be disposed of in
accordance with local, state, and federal laws and regulations.
1. Set the On/Off switch to "Off".
2. Turn the regulator knob counterclockwise to set the outlet pressure to zero.
3. Remove the air tool or accessory.