Porter-Cable N039112 Air Compressor User Manual


 
14 - ENG



Gauges
Quick
Connect

5. Remove the hose by removing the hose clamp. NOTE: The hose clamp is not
reusable. You must purchase a new hose clamp, see Replacement Parts in
the Service section or purchase a standard hose clamp at a local hardware
store.
6. Remove pump mounting screws securing pump (one on each side).
Hose
Clamp
Pump Mounting Screw
7. Carefully slide pump from brackets
Regulator

Pump
shown


way
and out of the way.
8. Using an adjustable wrench remove
the regulator manifold.
9. Apply pipe sealant to new regulator
manifold and assemble, tighten with
wrench.
10. Reapply pipe sealant to gauges,
quick connect, and safety valve.
11. Reassemble all components in reverse order of removal. Make sure to orient
gauges to read correctly and use wrenches to tighten all components.
STORAGE
Before you store the air compressor, make sure you do the following:
1. Review the Maintenance section on the preceding pages and perform
scheduled maintenance as necessary.
2. Drain water from air tank. See To Drain Tank under Maintenance.

.
3. Protect the electrical cord and air hose from damage (such as being stepped
onorrunover).Windthemlooselyaroundthecompressorhandle.
4. Store the air compressor in a clean and dry location.