Quadra-Fire QV36B-A Welding Consumables User Manual


 
40 Quadra-fire • QV32B-A, QV36B-A • 2014-900 Rev. F • 9/06
4
Maintaining and Servicing Your Fireplace
Fireplace Maintenance
Although the frequency of your fireplace servicing and main-
tenance will depend on use and the type of installation, you
should have a qualified service technician perform an appli-
ance check-up at the beginning of each heating season.
See the table below for specific guidelines regarding each
fireplace maintenance task.
IMPORTANT: TURN OFF THE GAS BEFORE SERVICING
YOUR FIREPLACE.
Replacing old ember material
Frequency: Once annually, during the checkup.
By: Qualified service technician.
Task: Brush away loose ember material near the burner.
Replace old ember material with pieces of Mystic Ember
following the directions in Placing Ember Material. New
ember material should be placed on top of the burner. Save
the remaining ember material and repeat this procedure at
your next servicing. For more information, see Placing
Ember Material.
Cleaning Burner and Controls
Frequency: Once annually.
By: Qualified service technician.
Task: Brush or vacuum the control compartment, fireplace
logs and burner areas surrounding the logs.
Checking Flame Patterns, Flame Height
Frequency: Periodically.
By: Qualified service technician/Home owner.
Task: Make a visual check of your fireplace’s flame patterns.
Make sure the flames are steady - not lifting or floating.
See Figure 46. The thermopile/thermocouple tips should
be covered with flame. See Figure 33.
Figure 46. Burner Flame Patterns
MAKE SURE THE FLAMES
ARE STEADY—NOT
LIFTING OR FLOATING.
Checking Vent System
Frequency: Before initial use and at least annually
thereafter, more frequently if possible.
By: Qualified service technician/Home owner.
Task: Inspect the external vent cap on a regular basis to
ensure that no debris is interfering with the flow of air. Inspect
entire vent system for proper function.
Cleaning Glass
Frequency: After the first 3 to 4 hours of use. As necessary
after initial cleaning.
By: Home owner.
Task: Remove and clean glass after the first 3 to 4 hours of
use. After the initial cleaning, clean as necessary, particularly
after adding new ember (flame colorant) material. Film
deposits on the inside of the glass should be cleaned off
using a household glass cleaner. NOTE: DO NOT handle
or attempt to clean the glass when it is hot and DO NOT
use abrasive cleaners.