VI. BATTERIES AND CHARGING
BATTERIES AND CHARGING
The Quantum Jazzy uses two long-lasting, 12-volt, deep-cycle batteries. These batteries are sealed and maintenance free. Since
they are sealed, there is no need to check the electrolyte (fluid) level. Deep-cycle batteries are designed to handle a longer and
deeper discharge. Though they are similar in appearance to automotive batteries, they are not interchangeable. Automotive
batteries are not designed to handle a long, deep discharge, and also are unsafe for use in power chairs.
WARNING! Battery posts, terminals, and related accessories contain lead and lead compounds. Wash
hands after handling.
Charging the Batteries
The battery charger is essential in providing long life for your power chair batteries. The battery charger is designed to optimize
your power chairs performance by charging the batteries safely, quickly, and easily. The charging system consists of the
charger, the charger fuse, and the ammeter. See figures 3 and 4. The onboard charger is located underneath the electronics tray.
See figure 4. The charger has an in-line fuse that protects the ammeter, which is located on the electronics tray for easy viewing.
The ammeter indicates the rate of charge necessary to fully recharge the batteries. It is also a good indication of whether or not
the charger is working. The ammeter and the charger are only functional when the charger power cord is plugged into a wall
outlet.
WARNING! You must recharge your Jazzys batteries with the supplied onboard or off-board charging
system. Do not use an automotive-type battery charger.
WARNING! Never use an extension cord to plug in your battery charger. Plug the charger directly into a
properly wired standard wall outlet.
To charge the batteries using the onboard charger:
1. Position the rear of your power chair close to a standard wall outlet.
2. Be certain the controller power is turned off and the freewheel levers are in the engaged position. See IV. The Quantum Jazzy
1400 Series.
3. Extend the charger AC power cord and plug it into the wall outlet. The Quantum Jazzy incorporates an inhibit function that
disables the power chair when the charger is plugged into a wall outlet.
4. The ammeter indicates how much charge is needed to fully charge the batteries. Wait about a minute for the charger to warm
up. The ammeter may move as high as 5.5 amps, then gradually move back down to 0 amps as the batteries charge.
5. We recommend you charge the batteries for 8 to 14 hours. As the batteries charge, the ammeter needle slowly drops to
zero. When the batteries are fully charged, the needle vibrates on or about the 0 mark on the ammeter scale.
6. When your power chairs batteries are fully charged, wind up the charger AC power cord using the hook and loop
strap and place the cord back into the power chairs electronics tray.
To charge the batteries using the off-board charger:
1. Position your power chair next to a standard wall outlet.
2. Be certain the controller power is turned off.
3. Plug the off-board charger into the off-board charger socket. See figures 20 and 22.
4. Plug the off-board charger into the wall outlet.
5. If it is a Pride off-board charger, then there are two lights in it. The red light indicates that power to the off-board charger is
on. The green light indicates that the batteries are fully charged. If it is not a Pride off-board charger, then follow the
instructions that came with it.
6. When the batteries are fully charged, unplug the off-board charger from the wall outlet and from the controller.