Windows 34699 N/A File system does not automatically
mount after a reboot due to
GetByHostName failure.
Do one of the following:
Add the server name to
the etc\hosts file on
the Windows client.
- or -
Type the IP address of
the machine in the
fsnameservers tab
instead of the machine
name.
All 34784 N/A When performing a cvcp
command from a Windows client
against a file with international
characters, a "cannot find file" error
is returned.
N/A
34737 N/A StorNext (CVFS) does not support
DriveImage7.
N/A
4534 N/A Files do not migrate by default
policy rules if time is set in the
future.
Verify that time settings on
all server and client
machines are
synchronized.
7576 N/A Install / Uninstall failures during
installation (permissions and NIS).
Contact ATAC:
In the USA:
800.827.3822
Outside the USA (toll
free): 00.800.9999.3822
ATAC Website:
www.adic.com/techsup
15372 N/A JNI FC-HBA drivers for Linux do
not support tape libraries.
N/A
16853 N/A Stopping DSM component causes
unwanted HA failover.
Refer to the StorNext
Product Bulletin #4:
http://
www.adic.com/us/collateral/
SNMS_ProdBull_4.pdf
22159 N/A HA Failover: Linter does not
automatically start on the standby
server when the active server
reaches 100% capacity on the local
file system.
Manually start SNSM
components using the
StorNext GUI.
34211 N/A On STK libraries, StorNext and
Extensible Drive Interface (XDI) do
not handle multiple Cartridge
Access Points (CAP).
Use only first CAP on multi-
CAP STK libraries.