RIDGID OF45175A Air Compressor User Manual


 
1. When not in use, compressor should be
stored in a cool dry place.
2. Tank should be drained of moisture.
3. Hose should be disconnected and hung
open ends down to allow any moisture
to drain.
15
The tank should be carefully inspected at
a minimum of once a year. Look for
cracks forming near the welds. If a crack
is detected, remove pressure from tank
immediately and replace.
Tank
Never attempt to repair or modi-
fy a tank! Welding, drilling or
any other modification will
weaken the tank resulting in
damage from rupture or explo-
sion. Always replace worn,
cracked or damaged tanks.
!
DANGER:
Drain liquid from tank daily.
NOTICE:
To change a filter, pull off the filter housing
cover. If filter element is dirty, replace ele-
ment or entire filter.
Filter Removal, Inspection and Replacement
This is an oilless type compressor requir-
ing no lubrication.
Lubrication
Storage
Operation Daily Weekly
Drain Tank
Check Air Filter
Check Safety Valve
Blow Dirt From Inside Motor
Maintenance Schedule