5
1 Specifications
1.1 CVW-EXA284 (H: 84 7/8”, L: 96 3/8”) / CVW-EXA224 (H: 84 7/8”, L: 144 5/8”)
Model Name CVW-EXA284
CVW-EXA224
General
Application: Medium Temperature (Fresh Produce) Medium Temperature (Fresh Produce)
Cooling Capacity:
1224 BTU/h/ft. (2,880W) 1224 BTU/h/ft. (4,321W)
Discharge Air: 34°F (1.11°C) 34°F (1.11°C)
Evaporator Temperature: 28°F (-2.22°C) 28°F (-2.22°C)
Defrost (Off-cycle)
Medium Temperature Medium Temperature
Frequency: (times per day) 6, once every 4 hours 6, once every 4 hours
Termination Temperature: 50.0°F 50.0°F
Failsafe/Duration: 30 minutes 30 minutes
Electrical
1-phase 120V
1-phase 120V
Anti-condensation Heater:
N/A N/A
N/A N/A
Standard:
195W 2.28A
285W 3.42A Fan
Motor
High Efficiency:
84W 1.29A
126W 1.93A
Exterior:
2 Rows of Lamps
110W 0.94A
2 Rows of Lamps
166W 1.42A
Top Panel
N/A N/A
Top Panel
N/A N/A
Interior:
Handrail
N/A N/A
Handrail
N/A N/A
Lights
Total:
Standard
110W 0.94A
Standard
166W 1.42A
Components
Anti-condensation Heater N/A N/A
Standard: SPFBE141 x 3 SPFBE141 x 3 , SPFBE91T x 2 Fan
Motor
High Efficiency:
SSC2B12CNHBV1 x 3 SSC2B12CNHBV1 x 3 , SSC2B12BVHBV1 x 2
Fan Blade Pitch:
Inside:#128×2, Outside:#128 x 1 Inside:#128 x 3, Outside:#117 x 2
Illumination: FO32/XP (T8) (Output 32W) FO32/XP (T8) (Output 32W)
Pipe Diameter: Liquid 3/8”, Suction 3/4” Liquid 3/8”, Suction 3/4”
Measurements
Outer Dimensions: 84 7/8” (H) × 42 1/2” (W) × 96 3/8” (L) 84 7/8” (H) × 42 1/2” (W) × 144 5/8” (L)
Open Space: 61 1/2” 61 1/2”
Display Area: 73.4 sq.ft. 110.1 sq.ft
Effective Capacity: 72.0 cu.ft. 108.0 cu.ft.
Weight: 620.5 lbs 892.0 lbs
Waste Outlet Dimensions: 1 1/2” 1 1/2”
Standard Ambient Conditions: Indoor temperature 75°F (24°C), relative humidity 55%, wind speed under 39.4 fpm.
All specifications are based upon temperature, humidity, and wind speed values equal to or less than Standard Ambient Conditions.
SANYO Cases described in this manual are designed for indoor use only. SANYO Cases should not be exposed to direct sunlight.
Fan Motors are available in Standard-type (AC Fan Motors) or High Efficiency-type (DC Fan Motors).
Display Area Effective Capacity data specification based on 4 (four) 20” shelves set at 0° (flat). Any variations from this specification will
affect overall data.