Schumacher 94085894 Battery Charger User Manual


 
5
Do not face the battery when making the nal connection.7.5
When disconnecting the charger, always do so in the reverse order of the 7.6
connecting procedure and break the rst connection while as far away
from the battery as practical.
A marine (boat) battery must be removed and charged on shore. To 7.7
charge it onboard requires equipment specially designed for marine use.
BATTERY CHARGING - AC CONNECTIONS8.
This battery charge is for use on nominal 120 volt circuits and requires a 8.1
dedicated 20A circuit.
DANGER – Never alter AC cord or plug provided – if it does not t the
outlet, have proper outlet installed by a qualied electrician. Improper
connection can result in a risk of an electric shock or re.
Recommended minimum AWG size for extension cords for battery 8.2
chargers
25 50 100 150
(7.6) (15.2) (30.5) (45.6)
0 2 18 18 18 16
2 3 18 18 16 14
3 4 18 18 16 14
4 5 18 18 14 12
5 6 18 16 14 12
6 8 18 16 12 10
8 10 18 14 12 10
10 12 16 14 10 8
12 14 16 12 10 8
14 16 16 12 10 8
16 18 14 12 8 8
18 20 14 12 8 6
a
If the input rating of a charger is given in watts rather than in
amperes, the corresponding ampere rating is to be determined
by dividing the wattage rating by the voltage rating ± for
example:
1250 watts/125 volts = 10 amperes
Length of cord, feet (m)
AWG size of cord
AC input rating,
amperes
a
But less
than
At least
Grounding Methods8.3
This charger must be properly grounded. Make sure the AC outlet you are
plugging it into is properly grounded per local codes and regulations. If it
is not, have one installed by a qualied service person. Do not remove or
bypass the grounding pin on the plug or receptacle.