Schumacher INC-2405A Battery Charger User Manual


 
10
When a battery is very cold, partially charged or sulfated, it will not draw 18.2
the full rated amperes from the charger. It is dangerous and damaging
to a battery to force higher amperage into it than it can effectively use in
recharging.
When an unknown operating problem arises, please read the complete 18.3
manual and call the customer service number for information. Doing so
will usually eliminate the need for return.
If the above solutions do not eliminate the problem or for
information about troubleshooting or replacement parts,
call toll-free from anywhere in the U.S.A.
1-800-621-5485
7:00 am to 5:00 pm Central Time Monday thru Friday
TECHNICAL SPECIFICATIONS19.
This charger is intended for use with lead-acid and gel-cell batteries only.
Electrical
Nominal Operating Voltage (VAC) 100 – 240
Input Voltage Range (VAC) 85 – 264
Input Current (A rsm max) 2.9 @ 85V 60Hz
Output Power (W) 120 nom. 130 max.
Output Current (A max) 5.0
Output Voltage (VDC nom./
range)
24 / 2 – 29.5
Mechanical
Case Black Anodized Aluminum
Dimensions (inches) 7 L x 5½ W x 2 H
Weight 1.80 lbs
Connections
AC Power Input C13 Male Socket
DC Power Output Adapters Option #1 – Battery Clamp Output Cord
Option #2 – 3-Pin XLR 3-12C Output Cord
Option #3 – 3/8” Dia. Ring Terminal Output
Cord