Schumacher MSC-2405 Battery Charger User Manual


 
11
BEFORE RETURNING FOR REPAIR18.
Please do not return for repair before speaking to a customer service
representative (1-800-621-5485).
When a charging problem arises, make certain that the battery is capable 18.1
of accepting a normal charge. Use a good battery to double check all con-
nections, AC outlet for a full 120-volts, charger clamps for correct polarity,
and the quality of the connections from the cables to the output connector
and from the output connector to the battery system. The output connec-
tors must be clean.
When a battery is very cold, partially charged or sulfated, it will not draw 18.2
the full rated amperes from the charger. It is dangerous and damaging
to a battery to force higher amperage into it than it can effectively use in
recharging.
When an unknown operating problem arises, please read the complete 18.3
manual and call the customer service number for information. Doing so
will usually eliminate the need for return.
TECHNICAL SPECIFICATIONS19.
This charger is intended for use with lead-acid and gel-cell batteries only.
Electrical
Nominal Operating Voltage (VAC) 100 – 240
Input Voltage Range (VAC) 85 – 264
Input Current (A rsm max) 2.9 @ 85V 60Hz
Output Power (W) 120 nom. 130 max.
Output Current (A max) 5.0
Output Voltage (VDC nom./
range)
24 / 2 – 29.5
Mechanical
Case Black Anodized Aluminum
Dimensions (inches) 7 L x 5½ W x 2 H
Weight 1.80 lbs
Connections
AC Power Input IEC 320/C14 Male on Cable
DC Power Output Adapters Option #1 – Battery Clamp Output Cord
Option #2 – 3-Pin XLR 3-12C Output Cord
Option #3 – 3/8” Dia. Ring Terminal Output
Cord