Soleus Air KFHHP-22 Welding System User Manual


 
Disassemble compressor
Unsolder the soldering points between the pipes and compressor;unscrew
the three nuts with washers at the foot of compressor;take out the compressor
compressor
(Refer to figure 7-25)
Figure
compressor nuts
Disassemble valves
Unsrew the two screws fixing the big valve;unsoldering the soldering
points between the big valve and air-return duct;remove big valve
(When unsoldering,use wet cloth to wrap the big valve completely
to prevent it from being harmed by high temperature.
Unscrew the 2 screws fixing small valve;unsolder the joint points
between small valve and fork type pipe;remove small valve
(Refer to figure 7-24)
small valve
screws
big valve
Disassemblle capillary
Unsolder the joint points between capillary and other pipelines;them it
can be removed
(Refer to figure 7-23)
capillary
Operating procedures/pictures
-22-