Spectra LL300-8 Laser Level User Manual


 
9
In order to avoid offset errors, the receiver should be used close to the elevation where the laser has been
set up.
If a remote control is available, the up and down arrow buttons can be used for ne adjustments.
LEVELING ACCURACY
In uences on the leveling accuracy
The overall accuracy of the unit can be in uenced by many factors:
factory accuracy;
temperature of the unit;
ambient in uences like rain, wind and temperature.
The factor that in uences on the unit’s accuracy most is the ambient temperature. Vertical differences in
temperature near the ground can divert the laser beam, similar to the heat waves seen on hot asphalt
streets.
This factor also applies to all optical measuring devices such as automatic levels and
theodolites.
Accuracy Check
To ensure job-site accuracy, you need a distance of 20 m (65 feet) between two walls A and B, where you will
execute 4 measuring operations on a tripod as follows (transit measurement).
Set the unit horizontally on a tripod near wall A and switch it on with the plus X-axis pointing towards wall A.
After the unit is level, mark the height of the laser beam using a receiver at wall A. Turn the entire unit 180°,
let it self-level and mark the center of the laser beam at wall B.
A
B
20m
1
1.1
1.2
Now, place the unit near wall B with the plus X-axis pointing towards wall B. After the unit is level, mark the
height of the laser beam at wall B. Turn the entire unit 180°, let it self-level and mark the center of the laser
beam at wall A. The difference (h) of the marked points at wall A shows the deviation.
041365_01_LL300_GB.indd 9 17.09.2004, 11:43:56 Uhr