Stanley Black & Decker MB05 Power Hammer User Manual


 
MB05 User Manual ◄ 15
This section describes how to nd and resolve problems users may experience. If a situation occurs that is not
covered, call your Stanley Customer Service representative for assistance.
WARNING
Inspecting the tool or installing parts with the hydraulic hoses connected can result in severe personal injury
or equipment damage. To prevent accidental startup, disconnect the hydraulic power before beginning any
inspection or installation task.
If symptoms of poor performance develop, the following chart can be used as a guide to correct the problem.
When diagnosing faults in operation of the tool, always check that the hydraulic power source is supplying the
correct hydraulic ow and pressure to the tool as listed in the table below. Use a owmeter known to be accurate.
Check the ow with the hydraulic oil temperature at least 80 °F/27 °C.
PROBLEM CAUSE SOLUTION
Breaker will not re. Low hydraulic oil level. Fill reservoir.
No ow to breaker. Have hydraulic circuit tested by
authorized dealer/distributor per
approved procedure.
Main relief set low.
Internal damage. Have unit serviced by an authorized
dealer/distributor.
Damaged quick couplers. Replace.
Breaker runs slowly. Low hydraulic ow Have hydraulic circuit tested by an
authorized dealer/distributor per
approved procedure.
Excessive heat build up.
Excessive nitrogen pressure. Have unit serviced by an authorized
dealer/distributor.
Internal leakage.
Breaker runs erratically. Low or excessive back-pressure. Have carrier serviced by an
authorized dealer/distributor.
Damaged switch or connection.
Relief set too low.
Internal damage.
Tool binding. Add grease to tool shank. Do not
pry while operating.
Breaker runs but at reduced power. Low accumulator charge. Have unit serviced by an authorized
dealer/distributor.
Excessive back-pressure.
Relief set too low.
Breaker leaks oil around tool bit and
tool bushing.
Lower seals failed. Have unit serviced by an authorized
dealer/distributor.
Hydraulic system overheats. Main relief set low. Have unit serviced by an authorized
dealer/distributor.
Insufcient cooling capability in
hydraulic circuit.
Line/hose size too small.
Excessive back-pressure.
TROUBLESHOOTING