JAM CLEARING PROCEDURE
D
isconnect tool from air supply before making adjustments or before attempting any
p
art assembly or disassembly.
O
n occasion nails can jam in the nose of a pneumatic nailer. This can be caused by striking a metal plate
i
n the wall, drywall screw, or some other hard object. The BT1855 and SX1838 feature open drive channel
architecture for jam clearing. To clear a jam follow this procedure:
1. Disconnect the tool from the air supply.
2
. Open the magazine by depressing the magazine release button and pulling open the magazine.
3
. Remove the jam fastener. In certain circumstances, pliers may be required to remove the fastener.
4. Close the magazine.
BT1855 JAM CLEARING
SX1838 JAM CLEARING