4
exposed areas with soap and water.Allowingdusttogetintoyourmouth,eyes,or
layontheskinmaypromoteabsorptionofharmfulchemicals.
WARNING: ALWAYS use safety glasses. Everyday eyeglasses are NOT safety
glasses. Also use face or dust mask if drilling operation is dusty. ALWAYS WEAR
CERTIFIED SAFETY EQUIPMENT:
• ANSIZ87.1eyeprotection(CAN/CPAZ94.3),
• ANSIS12.6(S3.19)hearingprotection,
• NOSH/OSHArespiratoryprotection.
WARNING: Use of this tool can generate and/or disperse dust, which may
cause serious and permanent respiratory or other injury. Always use NIOSH/OSHA
approvedrespiratoryprotectionappropriateforthedustexposure.Directparticlesaway
from face and body.
CAUTION: Wear appropriate hearing protection during use. Under some condi-
tionsanddurationofuse,noisefromthisproductmaycontributetohearingloss.
• Whenusinganextension
cord,besuretouseone
heavyenoughtocarrythe
current your product will
draw. An undersized cord
will cause a drop in line
voltageresultinginlossof
powerandoverheating.
The following table shows
the correct size to use
depending on cord length
and nameplate ampere
rating.Ifindoubt,usethe
nextheaviergage.The
smallerthegagenumber,theheavierthecord.
SYMBOLS
• The label on your tool may include the following symbols. The symbols and their
definitionsareasfollows:
V ..................volts A ................... amperes
Hz ................hertz W ..................watts
min ..............minutes ................alternating current
............direct current
n
o .................no load speed
................Class I Construction .................earthing terminal
(grounded) .................safety alert symbol
................Class II Construction …/min ..........revolutions or reciprocation
(double insulated) per minute
.............
Read instruction manual before use
................
Use proper respiratory protection
................Use proper eye protection .................
Use proper hearing protection
sfpm ............ surface feet per minute
FUNCTIONAL DESCRIPTION
1. Trigger switch
2.Lock-onbutton
3.Sawbladelockinglever
4. Saw blade
5. Shoesleeve
6. Shoe
7.Shoebevelinglever
8. Speed control wheel
9.Cuttingactionlever
10.LEDLight
A
Minimum Gage for Cord Sets
Volts Total Length of Cord in Feet
120V 0-25 26-50 51-100 101-150
(0-7,6m)(7,6-15,2m)(15,2-30,4m)(30,4-45,7m)
240V 0-50 51-100 101-200 201-300
(0-15,2m)(15,2-30,4m)(30,4-60,9m)(60,9-91,4m)
Ampere Rating
More Not more American Wire Gage
Than Than
0 - 6 18 16 16 14
6 - 10 18 16 14 12
10 - 12 16 16 14 12
12 - 16 14 12 NotRecommended
1
5
6
9
10
2
3
4
7
8