Sterling EX909 Grinder User Manual


 
Page 22
Department at 1-800-229-2919 for voltage modification
instructions.
3-7-1 Hopper Safety Disconnect
1. Turn the main disconnect to the ON position.
2. Press the granulator START button to start the machine.
3. Test the front base door and the hopper access door: unlatch
the two (2) latches and open the doors approximately two (2)
inches to verify that the machine shuts off.
4. Latch the (2) latches to close the doors and re-engage the
cutting chamber safety switch.
!!! DANGER !!!
If the machine does not shut off as a result of this test, disconnect the machine
from the power source immediately and call the Ball & Jewell
Service Department
at 1-800-229-2919.
3-7-2 Motor Rotation Direction
1. Turn the main disconnect to the ON position.
2. Press the granulator START button to start the machine.
3. Note the direction of the rotor rotation. It should be
counterclockwise when viewed from the right hand side of the
machine. If the rotor rotation is not as described, turn off the
machine, turn the main disconnect to OFF, and reverse any two
(2) incoming power leads.
3-7-3 Accessory Equipment
For granulators equipped with conveyors, vacuum systems, etc.,
test their operation by pressing the appropriate button.