Sterling SSV-05 Air Compressor User Manual


 
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 19 of 36
4-3 Basic Setting of the Filling Level in the Conveyor Hopper
The filling level in the conveyor hopper is mainly determined by the level sensor.
Figure 6: Conveyor Hopper
Filling Level Too Low
1. Using a screwdriver, turn the adjustment screw of the level sensor (A) ¼
rotation counter-clockwise.
2. Check the filling level during the next conveying procedure.
3. Repeat the process until the desired filling level in the conveyor hopper is
reached.
Filling Level Too High
1. Using a screwdriver, turn the adjustment screw (A) of the level sensor ¼
rotation clockwise.
2. Check the filling level during the next conveying procedure.
3. Repeat the process until the desired filling level in the conveyor hopper is
reached.