W & W Manufacturing X3 & X6 Battery Charger User Manual


 
of battery chemistries such as; Lithium Ion, Lithium Polymer, Nickel Cadmium and Nickel Metal Hydride.
Most mechanical shapes can be accommodated with a specially designed battery cup. See battery
Cup description for more information.
FEATURES
Analyzes, condition and charges Nickel Cadmium and Nickel Metal Hydride batteries.
Analyzes and charge lithium Ion and lithium polymer batteries.
Features a single button capable of multifunction and an easy to read display for a user interface.
Auto condition cycle for nickel batteries and life cycle mode for all batteries.
Quick Test (QT), determines the state of a battery, as well as one of two states
Optional thermal printer for status and result printing.
PC program available for more advance user interfacing and graph generation.
Embedded OEM parameters or user defined profiles in “Learn Mode”.
Prime mode, allows one to enable a Li-ion battery to be unlocked at the upper and lower end of
the Li-ion protective circuits range. Enabling Nickel based battery to acquire a charge to enable
the battery to be evaluated by the various modes of the X3 & X6.
OVERVIEW
The W&W Analyzer X3& X6 is a programmable battery tester and battery cycler capable of testing a variety
4
Batt>60% and Batt<60%
*
Universal cup
The Universal cup will allow one to evaluate batteries with different chemistries and cell counts within defined
specifications. The Universal cup has one memory location that can be programed the same as the Learn
Memory location in a standard cup.
During entry into the “Learn Mode”of the Universal cup, Battery Chemistry, Capacity, and the number of Cells
Are prompted for data entry. Follow the Directions below to enter data for the Learn Mode.
Data Range
Chemistry (Lithium Ion, Nickel Cadmium, and Nickel Metal Hydride)
Capacity 100 - 4000 maH
# Of Cells 1-12 NiCd and 1-4 Li-ion
Important: It is important that when testing
an UNKNOWN BATTERY in the learn mode that
you select the UNKNOWN state as opposed to
GOOD. You can not perform a valid Quick
test or an impedance test with the Universal cup.
One must observe the proper polarity when
connecting the battery to the Universal cup.
Should you connect the battery incorrectly,
you will hair a buzzing sound, reverse the leads.
At this point you may perform all the standard
operations that can be performed in stations; 2
3, 5 and 6 of the X3 and X6.
To change the cup settings for a different battery
or for different parameters for the same battery,
just repeat the Learn mod process again.
.
17
PUSH BUTTON ONCE
Display After “Turn On”
PUSH
PUSH
PUSH
NO ACTION
NO ACTION
ACTION
PUSH
PUSH
PUSH
PUSH
PUSH
SELECTING “ LEARN “ FOR
UNIVERSAL CUP
NO ACTION
NO ACTION
REMOVE BATTERY
BATT STATUS: UNKNOWN OR GOOD
<FUNCTION> TO CHANGE
ENTER THE NEW CHARGE
RATE: 1000 MA
ENTER NEW DIS -CHRG
RATE: C/2
LION 1CELL 1800MAH
CHRG: 1000MA C /:2
LEARN MODE COMPLETE
SELECTED CAPACITY =
1800 MAHR
PASS / FAIL LEVEL =
80% OF CAPACITY
STORING NEW
CONFIGURATION
REMOVE BATTERY
BATTERY TYPE =
LITHIUM ION
CELL COUNT =
2 CELLS
LEARN MODE
SELECTED
INSERT BATTERY
EMPTY
EMPTY
READY
Universal cup.